Containerized deployment
Factory-organized equipment reduces on-site battery assembly and improves project coordination.
Project-Scale Battery Energy Storage
A 516.096kWh containerized LiFePO4 battery platform for renewable integration, microgrids, industrial backup and project-scale dispatch.
1 / 6Product overview
BESS-PLUS 500GP is a containerized LiFePO4 battery platform with 516.096kWh of listed system energy and a 921.6V nominal DC architecture. It is intended for renewable integration, microgrids, industrial backup and project-level dispatch.
The designation 500GP is retained as the model name and is not interpreted as a technical value. Final project scope may include PCS, EMS, HVAC, fire protection, switchgear and auxiliary systems; the bill of materials must be defined for each quotation.
Choose the container format when factory-organized equipment, transportable project blocks and high-voltage PCS integration suit the site plan. A smaller cabinet may be more practical where energy demand, access or foundation limits do not justify a container.
Product advantages
Factory-organized equipment reduces on-site battery assembly and improves project coordination.
A repeatable project unit supports renewable and microgrid capacity planning.
The 921.6V nominal platform is designed for project PCS integration.
Selection logic
Coordinate a repeatable storage block with solar or wind generation.
Support planned islanded or grid-connected operating strategies through PCS and EMS.
Provide project-scale stored energy for selected industrial continuity requirements.
Verified technical data
Confirm the current datasheet, model scope and project conditions before specification or quotation.
| Electrical specification | BESS-PLUS 500GP Containerized Storage |
|---|---|
| Model | E-MATE 500GP |
| Battery module | 14.336 kWh, 51.2 V, 110 kg (242.5 lb) |
| Pack quantity | 18 × 2 = 36 |
| Cell chemistry | LFP (LiFePO4) |
| System energy | 516.096 kWh |
| Nominal voltage | 921.6 V |
| Operating voltage | 820.8–1,010.9 V |
| Output current | 140 A × 2 / 280 A × 2 |
| Display | SOC status display and LED indicators |
| Communication | Ethernet / CAN / RS485 |
| Service life | 6,000 cycles @ 80% DoD, 25°C, 0.5C, 60% EOL |
| Scalability | Yes |
| Operating modes | Grid-connected / grid-connected + standby / off-grid |
| Inverter compatibility | Major PCS brands; confirm against the compatibility list |
| Cell certifications | UN38.3 / IEC 62619 / UL 1642 |
| Battery pack certifications | UN38.3 / IEC 62619 / IEC 61000 |
| System certification | UL 9540; additional certifications available on request |
| Test condition | 100% DoD; charge/discharge at 0.2C and 25°C |
| Mechanical and environmental | BESS-PLUS 500GP Containerized Storage |
|---|---|
| Dimensions (W × D × H) | 2,991 × 2,438 × 2,591 mm (117.8 × 95.9 × 102 in) |
| Weight | 8,000 kg (17,637 lb) |
| Operating temperature | −20°C to 60°C (−4°F to 140°F) |
| Ambient humidity | ≤95% RH, non-condensing |
| Ingress protection | IP55 |
| Temperature derating | Applies from −10°C to 5°C and from 45°C to 55°C |
Compatibility and documents
Project fit
Frequently asked questions
Final scope may include battery, PCS, EMS, fire protection, HVAC, switchgear and auxiliary systems. Confirm the bill of materials for each quotation.
A structural engineer should confirm bearing load, anchoring, drainage, cable entry and service clearances based on the 8000kg listed weight.
Yes. Typical uses include solar and wind smoothing, microgrids and project-level energy dispatch.
The battery operating range is listed as 820.8-1010.9V. PCS compatibility must be checked across all operating conditions.
Ethernet, CAN and RS485 are listed. EMS architecture, remote access and cybersecurity should be defined during engineering.
Provide single-line diagrams, load/generation data, grid requirements, operating modes, site layout, climate, applicable standards and delivery constraints.
Project review
Share the application, electrical platform, load, capacity, runtime and installation location.